6 Dec 2021
A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.
The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.
To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.
It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.
This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.
Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.
With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
You can also download a copy of this Statement on choice of refrigerant as a pdf
References
9 Feb 2026
The IOR has released a new guidance note for those involved in recruitment, development or training within the UK RACHP sector, outlining how to harness the valuable skills that Veterans and Service Leavers bring to the industry and support their introduction into the RACHP profession.
5 Feb 2026
The Institute of Refrigeration has just released a report summarising the key findings and conclusions from its The Future of Training – Right Skills for the Right Job Survey, which it conducted among IOR members in October 2025 to explore future skills and qualification needs within the sector.
5 Feb 2026
The Department for Energy Security and Net Zero has recently released a series of upskilling videos for heat networks. These videos are to support upskilling operation and maintenance in the heat networks sector.
4 Feb 2026
Just downloaded the IOR Technician App? This video walks you through the essentials of using our app, step by step. You’ll see exactly where to tap, how to navigate key tools, and how to get the most out of the app’s main functions. It’s designed to help you feel confident and ready to use the app smoothly from the very start.
3 Feb 2026
The IOR and CIBSE are pleased to announce that they will be working together to provide their respective members with access to relevant technical events in 2026 as part of their commitment to members’ professional development and sharing of expertise.