A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

CallyBeaton 30941 RT Press

IOR Annual Dinner After Dinner Speaker Announced

6 Jan 2026

The organising committee is delighted to announce that broadcaster Cally Beaton will be this year’s after-dinner speaker at the IOR Annual Dinner. 

Live event
Programme Card 2026

New 2026 Programme Card of IOR Events

5 Jan 2026

Members should have received the latest IOR Programme Card, highlighting events that will take place over the coming months. We're kicking things off in January with two events!

 

News
EU Review

Review on EU Energy Labelling

18 Dec 2025

The European Commission is reviewing the energy label and ecodesign regulations for commercial refrigeration to assess how these Regulations have performed and to identify potential improvements.

News
MattHarveyMiriam

New IOR Education Outreach Manager

11 Dec 2025

The IOR is pleased to announce the appointment of Matt Harvey as its new Education Outreach Manager to lead education outreach initiatives with schools, vocational colleges, and employers.

News
F Gas Consultation Now Available 1

GB F Gas consultation - IOR response

11 Dec 2025

The consultation will shape future refrigerant use for our sector. Take part in this consultation to make the views of the RACHP industry heard. 

News