A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

Latest IOR Newsletter Now Available

13 Jan 2025

Members have been contributing to the latest IOR newsletter, highlighting the initiatives they're involved in with the Institute.

Publication

IOR Dinner - Join Us In A New Venue

9 Sep 2024

Bookings are now open for the IOR Annual Dinner and in 2025, the ‘Original Fridge Dinner’ will take place at an exciting new location – the London Hilton Bankside.

Live event

Members - Did You Get Your 125th Anniversary Sticker?

7 Jan 2025

The Institute is celebrating its 125th Anniversary and members can mark this with a special sticker commemorating this event!

News

Statement from the Environment Agency

19 Dec 2024

In response to the Institute of Refrigeration's query to the Environment Agency on the issue of cellar cooling being included in an upcoming ban on split air conditioning systems, the Environment Agency has sent us this statement.

News

Opportunity For Employers To Influence Future Skills

10 Dec 2024

BESA, on behalf of the Engineering Building Services Skills Authority (EBBSA,) are setting up Sector Groups (SG’s) in occupations within Building Services.  The SG’s purpose is to bring employers within specific occupation groups together to determine the roles that exist within that occupational area, thereafter determine a competency framework for these roles.  The IOR is pleased to be invited to support this work and to help co-ordinate outputs with its own plans to map skills needs and roles in the RACHP sector.

Consultation