A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

IOR Members Triumph at Women in Cooling Competition

2 Jun 2025

Congratulations to Chloe Jennings and Millie Edwards for winning first and third place in the Women in Cooling European Video Competition.

News

Retail sustainability with the enough project

28 May 2025

Lots to discuss at the "enough" retail workshop on commercial refrigeration and food chain emissions reduction on  27th May

News

New IOR Guidance Note on Coaching

22 May 2025

IOR has published its latest Education Guidance Note in the series, this time focusing on Coaching as a way of employers supporting engineering and technician development.  The Guidance Note (16) gives a guide to understanding the benefits of coaching, how this differs from mentoring and includes a useful list of organisations who can offer help with setting up coaching schemes or offer coaching.

Publication

Members Back Cold Chain To Be Part of UK's Critical Infrastructure

21 May 2025

IOR members showed their support for the Cold Chain Federation (CCF) campaign to recognise the Cold Chain as part of the UK's critical national infrastructure, as they attended the CCF's reception at the Houses of Parliament on 20th May.

News

First Keynote Announced For Adaptation 2025

8 May 2025

Expert in climate change adaptation Tim Fox will deliver a keynote talk at the IOR’s Adaptation 2025 conference detailing why cooling is now a “mission critical” service, essential to public health, food security, global commerce, and economic well-being.

Live event