6 Dec 2021
A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.
The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.
To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.
It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.
This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.
Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.
With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
You can also download a copy of this Statement on choice of refrigerant as a pdf
References
23 Apr 2026
The Institute of Refrigeration is the professional engineering body for all individuals working in RACHP. Find out more about the IOR here.
23 Apr 2026
Find out what the IOR can do for you: technical queries, safety codes of practice, new technologies and professional development.
23 Apr 2026
When you become a member of the Institute of Refrigeration you are joining a group of specialist experts driving the sector forward.
20 May 2026
The Tinsley Fund was set up in memory of Mike Tinsley and offers targeted financial help for people facing barriers to entering or progressing in the refrigeration and air conditioning sector.
20 May 2026
The deadline for the RAC and IOR National Student of the Year Cooling Industry Award has been extended to 29 May, which means there’s still time to put forward the exceptional students you know and help them gain the recognition they deserve.