A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

Latest IOR Newsletter Now Available

13 Jan 2025

Members have been contributing to the latest IOR newsletter, highlighting the initiatives they're involved in with the Institute.

Publication

Catch-Up on the IOR February TechTalk

10 Feb 2025

Catch up on the IOR February TechTalk which provided key insights into energy usage in the UK’s industrial refrigeration sector as part of the government project TICR (Transport, Industrial, Commercial Refrigeration).

Online event

Obituary - Ian Garvey FInstR

10 Feb 2025

It is with great sadness that we announce the passing of Ian Garvey. An IOR member since 2006, Ian played a pivotal role in shaping the industry through his work with the BRA Commercial Refrigerated Cabinets Section, contributing tirelessly for 25 years.

News

The IOR Northern Region Dinner Is Back!

9 Feb 2025

The IOR Northern Region Dinner is back after five years!

Live event

The IOR Is Turning The Spotlight On STEM

7 Feb 2025

This month's report from IOR President Lisa-Jayne Cook FInstR turns the spotlight on STEM—science, technology, engineering, and mathematics—and how we can inspire the next generation to get excited about refrigeration and engineering.

News