A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

Copy Of Copy Of Consultation On EN378

Call for Members’ to respond to Consultation on prEN378

21 Jul 2025

We encourage all members to engage in the consultation process by reading the draft standard and submitting comments through the on-line BSI portal, or by sending comments back to the Institute Technical Committee who will collate the comments and submit them on your behalf.

Consultation
Technician App

IOR RACHP EngTech Section Launches New Technician App

10 Jul 2025

The IOR’s RACHP EngTech Section is proud to announce the launch of an innovative mobile technician’s app, now available on the Apple App Store and Google Play Store.

News
P E Elections

President-Elect news 2025

29 Jul 2025

Three candidates for the next IOR President-Elect have been announced and an election will be held later this year.

News
ior logo square

Paul Moseley FInstR

24 Jul 2025

We regret to report the sad news that Paul Moseley a Fellow of the Institute and long term member has passed away

News
BR Award Logo

IOR Beyond Refrigeration Award - Now Open for Entries

21 Jul 2025

The IOR is calling for submissions for the Beyond Refrigeration Environmental Award! This prestigious annual award celebrates innovative UK projects that are making a real impact by cutting environmental emissions from cooling systems, driving us closer to vital net-zero goals.

Environment