A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.

The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.

To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.

It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.


This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.


Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.


With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.


The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References

The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.

You can also download a copy of this Statement on choice of refrigerant as a pdf

References

 

Recent posts

ISA LaunchEvent 1

IOR Industry Skills Alliance: meeting fully booked

2 Mar 2026

Fully Booked - wait list open. The launch of the IOR's Industry Skills Alliance for individuals interested in shaping the future of the skills agenda for the RACHP sector.  Find out more about the event and the role of the Skills Alliance here.

Live event
ior logo square

Members invited to feedback on update and review of IOR Constitution

24 Feb 2026

A review of the IOR Constitution has been carried out to ensure it complies with current Charity Commission guidance and improve the wording for clarity.  Open for consultation and comment by members until 30th April 2026.

Consultation
 ISA Full House

Skills Alliance Event Fully Booked - But Still Many Ways to Join In

23 Mar 2026

The IOR Skills Alliance's first meeting in Milton Keynes is at capacity, but there are still many ways to take part in the alliance's work.

Education
Craig Steve ACR

IOR Board of Trustees Members Honoured at the ACR Awards

23 Mar 2026

Congratulations to Steve Benton FInstR and Craig Girdlestone FInstR for this well‑deserved recognition for their dedicated, often behind‑the‑scenes contributions to the industry.

News
TechTalk Mar 26 1

Recording Now Available for March IOR TechTalk

9 Mar 2026

The recording for the IOR TechTalk on “Unscrambling the Refrigerant Clutter for the Future” on 5th March is now available from the IOR Webinar Channel.

Recording