6 Dec 2021
A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.
The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.
To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.
It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.
This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.
Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.
With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
You can also download a copy of this Statement on choice of refrigerant as a pdf
References
14 Jul 2025
IOR President Lisa-Jayne Cook FInstR was invited to discuss the increasing number of homes equipped with air conditioning on BBC Leicester's Breakfast Show.
10 Jul 2025
The IOR’s RACHP EngTech Section is proud to announce the launch of an innovative mobile technician’s app, now available on the Apple App Store and Google Play Store.
9 Jul 2025
From intermediate PH diagrams to coldroom sizing and equipment selection, the library of IOR Masterclasses keeps growing! Watch the recordings anytime, anywhere on the IOR webinar channel.
9 Jul 2025
Make sure you get your application form in by 1st August to stand for the IOR’s Trustees Elections held in the autumn.
8 Jul 2025
The revised EN378 standard is now open for public consultation until 26 August 2025.