6 Dec 2021
A new IOR Guidance Note 37 on Refrigerant Selection provides an overview of the critical points that should be considered in selecting refrigerant. Please download a copy of the Guidance Note to review.
The Guidance Note is of particular interest to equipment owners, operators and advisors making purchasing decisions that will influence the selection of refrigerant and equipment being installed now and in use well into the future. Members are encouraged to share this with their customers and equipment users.
To support Net Zero targets the IOR recommends that equipment designers, purchasers, owners and operators select a refrigerant with the lowest GWP possible.
It is often possible to use a refrigerant with a GWP of 10 or less (i.e., carbon dioxide, ammonia, hydrocarbon or HFO), but this may not always be practical. The IOR recommends that systems and equipment should only be installed using refrigerants with a GWP over 300 where a low GWP option with equal or better efficiency is not available. This recommendation is in line with the “low GWP” classification included in the UNEP RTOC reports and sector-specific trade associations which also quote the figure of GWP 300 as a maximum. GWP values above 300 are classed as “medium” or “high” in the RTOC classification.
This means that systems using “medium” or “high” GWP refrigerants should not be purchased or installed unless there is no lower GWP alternative for the application. For a full list of refrigerants and GWP values see the 2018 UNEP RTOC report or Annex E of BS EN 378-1:2016+A1:2020.
Where equipment using a refrigerant with a GWP greater than 300 is currently in use, a plan should be in place to replace the system at end of life with a lower GWP refrigerant where possible.
With the on-going phase down and quota restrictions on HFC refrigerants having the greatest impact on the availability of higher GWP refrigerants as well as certain use bans under national regulations, there are very good commercial and environmental reasons for moving to low GWP refrigerants.
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
References
The IOR Guidance Note 37 “Refrigerant Selection” gives a more complete explanation of all the criteria that should be adopted in selecting the most appropriate refrigerant for the application.
You can also download a copy of this Statement on choice of refrigerant as a pdf
References
3 Nov 2025
On 29 October, the IOR members met to share their reports on activity, plans and strategies for the future. Seven IOR committees met, including Membership, Education, Environment, Technical, Engineering Technician Group, Women in RACHP, and the Dinner Committee.
29 Oct 2025
At the IOR Annual General Meeting held on 29 October 2025, election results were announced. Stephen Gill FInstR was voted President-Elect, and Stephen Benton FInstR together with David Bostock FInstR were elected as Trustees to the IOR Board.
28 Oct 2025
The IOR and the ACES have signed a Memorandum of Understanding to strengthen collaboration and promote the exchange of ideas and expertise during the Clean Cooling Network Conference on the Sustainable Cold Chain for the Global South, taking place at the University of Birmingham from 28–29 October 2029.
22 Oct 2025
On 20th Oct the Department for Education (with others) published this document outlining future skills policy and new V levels to sit alongside A levels and T Levels in key sectors such as engineering. The RACHP industry will need to consider what these changes mean for our work to promote skills and careers to ensure sufficient supply of well trained new entrants to our sector. IOR education committee members are digesting the content...
21 Oct 2025
The IOR’s RACHP EngTech Section innovative mobile technician’s app has over 200 subscribers!