Looking for previously purchased publications?
Search publications 1899-2013 in our archives
Non-member price: £48.00
Member price: Free
Safety Code of Practice for Ammonia Refrigerant R717 (Group B2L).
The publication provides essential industry guidance for owners, designers, installers and operators of vapour compression refrigerating systems that use ammonia refrigerant. It covers properties of refrigerants, decommissioning, testing and maintenance as well as design issues with useful appendices such as typical schedules for inspection and maintenance, system register details, machinery rooms, definitions and an updated list of relevant standards. The Code has been prepared by the IOR Technical Committee as a reference source and guide to interpretation of current safety standards such as BS EN378:2016 and legal requirements such as PED, PSSR and PUWER.
The IOR publishes four Safety Codes of Practice specific to refrigerant type.
The Code is supplied as a 85 page PDF.
Updates:
May 2019 - addendum added Section 11: CLP and DSEAR
Aug 2019 - minor text updated to Appendix F Section 4.1
Members - you must be signed in to download this publication for free
Not a member? Find out how you can join at www.ior.org.uk/membership
Full Contents list
Section 1 – Scope and Limitations
Section 2 – Relevant Properties of Ammonia
2.1 Physical properties
2.2 Chemical Properties and Potential Hazards
Section 3 – Design of Components
3.1 General
3.2 Component Design and Test Pressures
3.3 Compressors
3.4 Pressure Vessels and Heat Exchangers
3.5 Liquid Ammonia Pumps
3.6 Ammonia Control Valves and Sensing Devices
Section 4 – System Design and Installation
4.1 General
4.2 Material Selection
4.3 Steel Piping Systems
4.4 Copper Pipework
4.5 Location and Arrangement of Piping
4.6 Arrangement of Isolating Valves
4.7 Instrumentation
4.8 Protection against Excess Pressure
4.9 Protection against Environmental Effects
4.10 Notification to Local Authorities
4.11 Refrigerant Detection
4.12 System Labelling
4.13 Allowable Refrigerant Charge
4.14 Protection for Indirect Circuits
4.15 Additional Requirements for Ammonia
Section 5 – System Testing
5.1 General
5.2 Strength Test Procedure 5.3 Tightness Test Procedure
5.4 Test Certificates 7
Section 6 – Commissioning of New Installations
6.1 General
6.2 Evacuation and Dehydration
6.3 Charging
6.4 Protection Devices
Section 7 – Inspection and Maintenance
7.1 General
7.2 System Log
7.3 Routine Inspection
7.4 Major Inspection
7.5 Pressure System Examination
Section 8 ‐ Documentation
8.1 General
8.2 Risk Assessment
8.3 Health and Safety File
8.4 Written Scheme of Examination and Records
8.5 Commissioning Records
8.6 Refrigerant Inventory Record
8.7 Contingency Provisions
8.8 The System Register
8.9 System Log
8.10 Instruction Manuals
Section 9 ‐ Decommissioning
9.1 General
9.2 Recovered Refrigerant
Section 10 – References, Standards and Legislation (all refrigerants)
Section 11 - Addendum: CLP and DSEAR
Appendix A ‐Definitions
Appendix B – Maximum Allowable Pressure and Strength Test Procedure
Appendix C – Pneumatic Strength Pressure Test Procedure
Appendix D – Marking and Name Plate Data
Appendix E ‐ Handling, Transport and Storage of Refrigerant Cylinders
Appendix F – Commissioning of New Installations
Appendix G – Machinery Rooms and Auxiliary Safety Equipment
Appendix H – Typical Schedule for Inspection and Maintenance
Appendix I – Sample Details for Register
Appendix J ‐ Sample Compressor Operating Data and System Log
Appendix K – IOR Policy on Refrigerant Choice
Appendix L ‐ Stress Corrosion Cracking
Log in to your account (top right) to download this free guide.